PPPL-4739

Considerations For Contractile Electroactive Materials and Actuators

Authors: Lenore Rasmussen, Lewis D. Meixler and Charles A. Gentile

Abstract: Electroactive polymers (EAPs) that bend, swell, ripple (first generation materials), and now contract with low electric input (new development) have been produced. The mechanism of contraction is not well understood. Radionuclide-labeled experiments, molecular modeling, electrolyte experiments, pH experiments, and an ionic concentration experiment were used to determine the chain of events that occur during contraction and, reciprocally, expansion when the polarity is reversed, in these ionic EAPs. Plasma treatment of the electrodes, along with other strategies, allows for the embedded electrodes and the EAP material of the actuator to work and move as a unit, with no detachment, by significantly improving the metal-polymer interface, analogous to nerves and tendons moving with muscles during movement. Challenges involved with prototyping actuation using contractile EAPs are also discussed.

__________________________________________________

Submitted to: Proceedings of SPIE, (March, 2012)

__________________________________________________

Download PPPL-4739 (pdf 1.52 MB 13 pp)
__________________________________________________