PPPL-4875

STELLOPT Modeling of the 3D Diagnostic Response in ITER

Authors: S. A. Lazerson and I.T. Chapman

Abstract:
The ITER three dimensional diagnostic response to an n=3 resonant magnetic perturbation is modeled using the STELLOPT code. The in-vessel coils apply a resonant magnetic perturbation (RMP) fi eld which generates a 4 cm edge displacement from axisymmetry as modeled by the VMEC 3D equilibrium code. Forward modeling of flux loop and magnetic probe response with the DIAGNO code indicates up to 20 % changes in measured plasma signals. Simulated LIDAR measurements of electron temperature indicate 2 cm shifts on the low field side of the plasma. This suggests that the ITER diagnostic will be able to diagnose the 3D structure of the equilibria.
__________________________________________________

Submitted to: Plasma Physics and Controlled Fusion (May 2013)

__________________________________________________

Download PPPL-4875 (pdf KB 12 pp)
__________________________________________________